Innovation for Your Benefit! Adaptable for Your Needs!
Details of BAUER System Technology
 |
| MAXI Verticus -
Standard with enclosure |
| |
 |
| Open Vertical -
MAXI Verticus without enclosure, shown with IP5 Air Processing System with Securus |
Enclosure
A standard or custom
designed enclosure adds
an attractive finished
look to your industrial
compressor and
improves the cooling
of the compressor by
allowing only cool air
into the enclosure while
expelling the hot air out
of and away from the
enclosure.
Enclosures are
designed to permit full
accessibility to internal
components for inspection
and maintenance. Sound
attenuation material and special
sound attenuating designs are available.
Instrumentation
All compressor packages include
instrumentation and monitoring
devices for supervising the
compressor’s performance.
Standard features include:
Gauge Panel (optional on some models)
Hourmeter
Operator Keypad
Emergency Stop Pushbutton
Back-lit LCD Display for Operational, Maintenance & Troubleshooting Messages
All instrumentation and control devices
are mounted for maximum visibility
and easy accessibility for the operator.
Each device is identified with a label.
Air Processing
Clean compressed air is
essential for the proper
operation of a high
pressure compressed air
system. BAUER uses a
coalescing separator to
remove condensed oil
and water from the cooled
compressed air leaving
the aftercooler. The oil and
water emulsion collects in the bottom of the separator
and is drained by the automatic
condensate drain. For applications
that require additional processing, a
refrigerated air cooler can be installed
upstream of the final separator or a
BAUER high pressure processing
system can be installed downstream
of the final separator.
Please visit the "The Complete Package" page for full details
 |
| Proprietary Compressor Controller |
 |
| Standard BAUER Compressor
Control System |
|
| Wiring Harness Connector bottom view |
| Solid State Pressure
Switch with Built-in
Pressure Readout and
Adjustable Deadband |
|
| Display is back-lit green for normal conditions,
orange for warning conditions and red for alarm
conditions, warning and alarm conditions include
text messages for troubleshooting assistance.
Display includes Operator Keypad for Off/On
control and alarm reset. |
|
Compressor Controls
All compressor packages include a
factory installed, UL approved, PLC-based
electrical control system that includes all
of the components and features required to
safely operate a high pressure compressor.
The electrical enclosure is NEMA 4 rated.
Standard Features:
Back-lit LCD Display for
Operational, Maintenance & Troubleshooting Messages
Full Voltage Motor Starter
Overload Relay with Manual Reset
Fused Transformer
Automatic Condensate Drain (ACD)
control with Test Pushbutton
Condensate Collector with Alarm
for High Condensate Level
Pressure Switch for Low
Oil Pressure Protection
Solid State Pressure Switch for
Automatic Start-Stop Control
Temperature Switch for
High Temperature Protection
Adjustable Excessive Run Timer
Load Cycle Counter
Emergency Stop Pushbutton
Operator Keypad
Warning and Alarm Indication
Color-coded Wiring Harness
Battery Back-Up
Available Features:
Soft Start
Disconnect
SECURUS®
TEFC Motor
Audible Alarm
Constant Speed Unloader
Explosion Proof Motor and Controls
Gas Detectors for a Variety of Industrial Gases
|