System Components
SCBA Fill Stations
Containment Fill Stations - Stationary & Mobile
BAUER offers only Independently Tested Containment Fill Stations which were found to protect the operator from overpressure and fragmentation per NFPA 1901.
 |
 |
 |
| CFSII-1S |
CFSII-2S |
CFSII-3S |
One, Two, or Three Fill Positions Complete with Cylinder
Scuff Guard, SCBA Fill Connection, Fill Hose and Bleed Valve
Safety Door Interlock
Fill Control Panel with Adjustable Regulator, Relief Valve,
Manual Control Valve and Pressure Gauge for Each Fill Position
(S version only)
Mounted Cascade Panels Available with Single or Dual
Function Capability (2S or 3S models)
CFSII M Versions Designed for Use with Remote
Air Distribution Panel
Mounting Base is Standard on “S” Version
and Optional on “M” Version
Technical Data
| Model |
Dimensions Inches |
Weight |
| L |
W |
H |
lbs. |
| CFSII-1S |
18 |
21 |
55 |
433 |
| CFSII-1M |
18 |
21 |
39 |
360 |
| CFSII-2S |
30 |
21 |
53 |
670 |
| CFSII-2M |
30 |
21 |
39 |
550 |
| CFSII-3S |
41 |
21 |
53 |
905 |
| CFSII-3M |
41 |
21 |
39 |
740 |
Oxygen Fill Stations - Stationary & Mobile
When your fill station needs require oxygen compatibility, look to BAUER to fulfill your needs.
Thoroughly proof tested by an independent third party lab with oxygen as the process gas,
rest assured containment means just that when you purchase BAUER.
 |
 |
| OXY-1S |
OXY-2S |
Single or Tandem Fill Positions
Mounted Oxygen
Management Control Panel
The Entire System is
Oxygen Cleaned Prior to Shipment
Technical Data
| Model |
Dimensions Inches |
Weight |
| L |
W |
H |
lbs. |
| OXY-1S |
18 |
21 |
55 |
433 |
| OXY-1M |
18 |
21 |
39 |
360 |
| OXY-2S |
30 |
21 |
53 |
670 |
| OXY-2M |
30 |
21 |
39 |
550 |
Fill Panels
 |
 |
 |
BFP-2 BASIC FILL PANEL
Shown with Two Fill Whips and SCUBA Connectors |
HIGH PRESSURE BRIEFCASE FILL
21.5"L - 9"W - 15"H |
BF450-FCP
18"L - 12"W - 38"H |
Convertible Fill Panels
BFP - Basic Fill Panel Designed for Conversion to a Cascade Panel. Suitable
for Wall Mounting or for Attachment to DOT or ASME Storage Cylinders. Includes
an Adjustable Regulator, Inlet/Outlet Gauges, Relief Valve, Fill Control Valves and
Inlet Port for Storage Refill. (Available with Two or Four Fill Whips.)
BFP/CSCD - the Designation for Cascade Fill Includes a Shut-Off Valve and
Gauge for up to Four Banks of Storage. This Feature can be Factory Installed or
Easily Added Later by the User.
Briefcase Fill Panels
Available in High and Low Pressure Versions Supplied in Lockable Carrying Case.
Wall Mount Fill Control Panel
BF450-FCP Four Bank Fill Control Panel for Dual Function Cascade Control. Panel includes Adjustable Regulator, Air Inlet and Outlet Gauges, Fill Control Valves, Bank Valves and Gauges, and an Air Direction Valve allowing Single Point Air Management.
|